Thinking about rooftop solar: enter your monthly electricity use, your area's peak sun hours and the panel wattage you are considering, and get the number of panels, the system size in kW and the roof area it needs. (No unit switch here — electricity is the same everywhere; roof area is shown in both m² and ft².)
Rough averages: UK and northern Europe 2.5–3.5, central Europe 3–4, Mediterranean 4.5–5.5, US Sun Belt 5–6.5, Pakistan and northern India 5–6, Gulf states 5.5–6.5, most of Australia 4.5–6. Your installer or a solar irradiance map for your city will give a better figure.
A typical modern residential panel is about 1.9 m² (roughly 1.75 × 1.1 m). Measure the usable, unshaded roof slope, subtract space for ridges, chimneys and setbacks, and divide by 1.9 — a 40 m² slope fits around 20 panels.
Panels rarely deliver their lab rating in real life: the inverter converts at 95–98%, cables lose a little, and heat, dust and partial shading take more. 14–20% total is realistic; this calculator defaults to 15%. Ignoring losses is the most common reason home systems under-produce.
Daily use = Monthly kWh ÷ 30
Required system (kW) = Daily use ÷ (Peak sun hours × (1 − Losses %))
Panels = ceil( Required kW × 1000 ÷ Panel wattage )
One 'peak sun hour' is one hour of full-strength sun (1,000 W/m²) — a day's total sunshine expressed in those hours. Roof area assumes a typical residential panel footprint of about 1.9 m² (20 ft²).
Usually close to it, sized on annual rather than monthly production. In many places exported surplus is paid far less than imported electricity costs, so a system matched to your daytime use often pays back faster than the biggest system that fits.
Not for the panels to work — a grid-tied system simply imports at night. Batteries add resilience during outages and let you use more of your own solar in the evening, but they are a separate cost decision; this calculator sizes the array only.
Most residential panels carry a 25-year performance warranty (typically 85–90% of original output at year 25) and degrade about 0.5% per year. Inverters usually need replacing once, around year 10–15.
Add this calculator to your own website or blog — it is completely free, needs no sign-up, and always shows the latest version. Copy the code below and paste it into your page where you want the calculator to appear. Keeping the small “Powered by Loona Automation” credit line under the embed helps keep this tool free — but you are free to style or remove it; the tool works either way.